362 research outputs found

    Modality, Potentiality and Contradiction in Quantum Mechanics

    Get PDF
    In [11], Newton da Costa together with the author of this paper argued in favor of the possibility to consider quantum superpositions in terms of a paraconsistent approach. We claimed that, even though most interpretations of quantum mechanics (QM) attempt to escape contradictions, there are many hints that indicate it could be worth while to engage in a research of this kind. Recently, Arenhart and Krause [1, 2, 3] have raised several arguments against this approach and claimed that, taking into account the square of opposition, quantum superpositions are better understood in terms of contrariety propositions rather than contradictory propositions. In [17] we defended the Paraconsistent Approach to Quantum Superpositions (PAQS) and provided arguments in favor of its development. In the present paper we attempt to analyze the meanings of modality, potentiality and contradiction in QM, and provide further arguments of why the PAQS is better suited, than the Contrariety Approach to Quantum Superpositions (CAQS) proposed by Arenhart and Krause, to face the interpretational questions that quantum technology is forcing us to consider.Comment: Published in: New Directions in Paraconsistent Logic, J-Y B\'eziau M. Chakraborty & S. Dutta (Eds.), Springer, in press. arXiv admin note: text overlap with arXiv:1404.518

    Carnot cycle for an oscillator

    Get PDF
    Carnot established in 1824 that the efficiency of cyclic engines operating between a hot bath at absolute temperature ThotT_{hot} and a bath at a lower temperature TcoldT_{cold} cannot exceed 1−Tcold/Thot1-T_{cold}/T_{hot}. We show that linear oscillators alternately in contact with hot and cold baths obey this principle in the quantum as well as in the classical regime. The expression of the work performed is derived from a simple prescription. Reversible and non-reversible cycles are illustrated. The paper begins with historical considerations and is essentially self-contained.Comment: 19 pages, 3 figures, sumitted to European Journal of Physics Changed content: Fluctuations are considere

    Enhancement of feline immunodeficiency virus infection after immunization with envelope glycoprotein subunit vaccines.

    Get PDF
    Cats were immunized three times with different recombinant feline immunodeficiency virus (FIV) candidate vaccines. Recombinant vaccinia virus (rVV)-expressed envelope glycoprotein with (vGR657) or without (vGR657 x 15) the cleavage site and an FIV envelope bacterial fusion protein (beta-Galactosidase-Env) were incorporated into immune-stimulating complexes or adjuvanted with Quil A. Although all immunized cats developed antibodies against the envelope protein, only the cats vaccinated with the rVV-expressed envelope glycoproteins developed antibodies which neutralized FIV infection of Crandell feline kidney cells. These antibodies failed to neutralize infection of thymocytes with a molecularly cloned homologous FIV. After the third immunization the cats were challenged with homologous FIV. Two weeks after challenge the cell-associated viral load proved to be significantly higher in the cats immunized with vGR657 and vGR657 x 15 than in the other cats. The cats immunized with vGR657 and vGR657 x 15 also developed antibodies against the Gag proteins more rapidly than the cats immunized with beta-Galactosidase-Env or the control cats. This suggested that immunization with rVV-expressed glycoprotein of FIV results in enhanced infectivity of FIV. It was shown that the observed enhancement could be transferred to naive cats with plasma collected at the day of challenge

    Insights in a restricted temporary pacemaker strategy in a lean transcatheter aortic valve implantation program

    Get PDF
    OBJECTIVES: To study the safety and feasibility of a restrictive temporary‐RV‐pacemaker use and to evaluate the need for temporary pacemaker insertion for failed left ventricular (LV) pacing ability (no ventricular capture) or occurrence of high‐degree AV‐blocks mandating continuous pacing. BACKGROUND: Ventricular pacing remains an essential part of contemporary transcatheter aortic valve implantation (TAVI). A temporary‐right‐ventricle (RV)‐pacemaker lead is the standard approach for transient pacing during TAVI but requires central venous access. METHODS: An observational registry including 672 patients who underwent TAVI between June 2018 and December 2020. Patients received pacing on the wire when necessary, unless there was a high‐anticipated risk for conduction disturbances post‐TAVI, based on the baseline‐ECG. The follow‐up period was 30 days. RESULTS: A temporary‐RV‐pacemaker lead (RVP‐cohort) was inserted in 45 patients, pacing on the wire (LVP‐cohort) in 488 patients, and no pacing (NoP‐cohort) in 139 patients. A bailout temporary pacemaker was implanted in 14 patients (10.1%) in the NoP‐cohort and in 24 patients (4.9%) in the LVP‐cohort. One patient in the LVP‐cohort needed an RV‐pacemaker for incomplete ventricular capture. Procedure time was significantly longer in the RVP‐cohort (68 min [IQR 52–88.] vs. 55 min [IQR 44–72] in NoP‐cohort and 55 min [IQR 43–71] in the LVP‐cohort [p < 0.005]). Procedural high‐degree AV‐block occurred most often in the RVP‐cohort (45% vs. 14% in the LVP and 16% in the NoP‐cohort [p ≀ 0.001]). Need for new PPI occurred in 47% in the RVP‐cohort, versus 20% in the NoP‐cohort and 11% in the LVP‐cohort (p ≀ 0.001). CONCLUSION: A restricted RV‐pacemaker strategy is safe and shortens procedure time. The majority of TAVI‐procedures do not require a temporary‐RV‐pacemaker

    Measurement of mechanical vibrations excited in aluminium resonators by 0.6 GeV electrons

    Get PDF
    We present measurements of mechanical vibrations induced by 0.6 GeV electrons impinging on cylindrical and spherical aluminium resonators. To monitor the amplitude of the resonator's vibrational modes we used piezoelectric ceramic sensors, calibrated by standard accelerometers. Calculations using the thermo-acoustic conversion model, agree well with the experimental data, as demonstrated by the specific variation of the excitation strengths with the absorbed energy, and with the traversing particles' track positions. For the first longitudinal mode of the cylindrical resonator we measured a conversion factor of 7.4 +- 1.4 nm/J, confirming the model value of 10 nm/J. Also, for the spherical resonator, we found the model values for the L=2 and L=1 mode amplitudes to be consistent with our measurement. We thus have confirmed the applicability of the model, and we note that calculations based on the model have shown that next generation resonant mass gravitational wave detectors can only be expected to reach their intended ultra high sensitivity if they will be shielded by an appreciable amount of rock, where a veto detector can reduce the background of remaining impinging cosmic rays effectively.Comment: Tex-Article with epsfile, 34 pages including 13 figures and 5 tables. To be published in Rev. Scient. Instr., May 200

    The fidelity of dynamic signaling by noisy biomolecular networks

    Get PDF
    This is the final version of the article. Available from Public Library of Science via the DOI in this record.Cells live in changing, dynamic environments. To understand cellular decision-making, we must therefore understand how fluctuating inputs are processed by noisy biomolecular networks. Here we present a general methodology for analyzing the fidelity with which different statistics of a fluctuating input are represented, or encoded, in the output of a signaling system over time. We identify two orthogonal sources of error that corrupt perfect representation of the signal: dynamical error, which occurs when the network responds on average to other features of the input trajectory as well as to the signal of interest, and mechanistic error, which occurs because biochemical reactions comprising the signaling mechanism are stochastic. Trade-offs between these two errors can determine the system's fidelity. By developing mathematical approaches to derive dynamics conditional on input trajectories we can show, for example, that increased biochemical noise (mechanistic error) can improve fidelity and that both negative and positive feedback degrade fidelity, for standard models of genetic autoregulation. For a group of cells, the fidelity of the collective output exceeds that of an individual cell and negative feedback then typically becomes beneficial. We can also predict the dynamic signal for which a given system has highest fidelity and, conversely, how to modify the network design to maximize fidelity for a given dynamic signal. Our approach is general, has applications to both systems and synthetic biology, and will help underpin studies of cellular behavior in natural, dynamic environments.We acknowledge support from a Medical Research Council and Engineering and Physical Sciences Council funded Fellowship in Biomedical Informatics (CGB) and a Scottish Universities Life Sciences Alliance chair in Systems Biology (PSS). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript
    • 

    corecore